Danfoss Ignition Transformers EBI

Danfoss manufacturers, exporters, suppliers for 1 or 2 pole ignition transformers. These EBI4, EBI4 C and EBI4 HP series is a new generation of environmentally friendly ignition transformers for small and medium size oil and gas boilers, burners, furnaces, ovens, incinerators and kilns and especially designed to operate with constant ignition at ambient temperatures up to 35°C. They are also applicable where a high ED% is required or intermittent operation is not sufficient. These are especially designed for applications where high power ignition is required. Ignition transformer is also known as ignition coil (also called a spark coil).

Type Code: EBI4 1P
Code Number: 052F4040
Main primary voltage connection: 230 V – 0.25 A – 50/60 Hz – 60 VA
Secondary connection* Short circuit current Frequency: 12 kV amp. 40 mA (rms) 20 kHz
ED in 3 minutes (cutting in): 33% at 60 °C
Ambient temperature: –10°C to +60 °C
Storage temperature: –25°C to +85 °C
Enclosure: IP 40 (Not for secondary connections)
EMC (Generic Standard): Emission EN 55014-1, Immunity EN 55014-2
Primary connection: • 3 × 0.5 mm2 standard cable with special plug
Secondary connections: 1 × Ø4 mm plugs (1 Pole)
Earth connection: Through the primary cable
Distance between electrodes: Recommended 2.5 mm to 5.0 mm
Weight: 235 g

Type Code: EBI4 M
Code Number: 052F4038
Main primary voltage connection: 230 V – 0.25 A – 50/60 Hz – 60 VA
Secondary connection* Short circuit current Frequency: 2 × 7.5 kV amp. 40 mA (rms) 20 kHz
ED in 3 minutes (cutting in): 33% at 60 °C
Ambient temperature: –10°C to +60 °C
Storage temperature: –25°C to +85 °C
Enclosure: IP 40 (Not for secondary connections)
EMC (Generic Standard): Emission EN 55014-1, Immunity EN 55014-2
Primary connection: • 3 × 0.5 mm2 standard cable with special plug
Secondary connections: 2 × Ø4 mm plugs (2 Pole)
Earth connection: Through the primary cable
Distance between electrodes: Recommended 2.5 mm to 5.0 mm
Weight: 235 g

×